logo
Contact Us

Contact Person : Phoebe Yu

Phone Number : 8618620854039

Whatsapp : +8618620854039

Free call

Highly Accurate Multi-Gas Analyzer 2s Analysis Time ≤0.2% Measurement Uncertainty for Industrial

Minimum Order Quantity : 1 Price : Negotiable
Packaging Details : Customized Packaging Delivery Time : 90-120 working days
Payment Terms : TT Supply Ability : 20 PCS/90-120 days
Place of Origin: CHINA Brand Name: JINSP
Certification: CE ISO9001 Model Number: RS2600PAT
Document: Product Brochure PDF

Detail Information

Laser Wavelength: 532nm Spectral Range: 200 ~ 4200 Cm-1
Resolution: ≤ 8 Cm-1 At Full Spectral Range Power Supply: 100 ~ 240 VAC,50 ~ 60 Hz
Analysis Time: 2 Seconds Measurement Uncertainty: ≤0.2%
Highlight:

Industrial Multi-Gas Analyzer

,

2s Analysis Time Multi-Gas Analyzer

,

Highly Accurate Multi-Gas Analyzer

Product Description

Highly Accurate Multi-Gas Analyzer
2s Analysis Time ≤0.2% Measurement Uncertainty for Industrial Applications
Key Specifications
Laser wavelength 532nm
Spectral range 200 ~ 4200 cm-1
Resolution ≤ 8 cm-1 at full spectral range
Power supply 100 ~ 240 VAC,50 ~ 60 Hz
Analysis time 2 seconds
Measurement uncertainty ≤0.2%
Product Overview

The RS2600PAT Online Raman Multi-Gas Analyzer from JINSP® utilizes Raman spectroscopy technology to detect all gases except noble gases, enabling simultaneous online analysis of multiple gases with exceptional accuracy.

Highly Accurate Multi-Gas Analyzer 2s Analysis Time ≤0.2% Measurement Uncertainty for Industrial 0
Detection Capabilities
  • Petrochemical industry: CH4, C2H6, C3H8, C2H4, and other alkane, alkene and alkyne gases
  • Fluorine chemical industry: F2, BF3, PF5, Cl2, HCl, HF and other corrosive gases
  • Metallurgical industry: N2, H2, O2, CO2, CO, etc.
Technical Highlights
  • Multi-component analysis: Simultaneous online detection of multiple gases
  • Universal detection: >500 detectable gas types (excluding noble gases)
  • Pressure-independent: Quantification unaffected by sample gas pressure changes
  • Rapid response: Complete detection within seconds
  • Wide quantitative range: From ppm level detection up to 100% concentration
Highly Accurate Multi-Gas Analyzer 2s Analysis Time ≤0.2% Measurement Uncertainty for Industrial 1
Detailed Specifications
Components N2, H2, O2, CO, CO2, H2S, CmHn, etc.
Laser excitation wavelength 532 ± 0.5 nm
Spectral coverage 200 ~ 4200 cm-1
Spectral resolution ≤8 cm-1 at full spectral range
Air circuit interface 6 mm standard tube fitting (3 mm, 1/8'', and 1/4'' optional)
Explosion-proof rating ExdbebibmbpxbIICT4Gb / ExtbibmbIIICT135ºCDb
Input voltage 100~240 VAC, 50~60 Hz
Sample gas temperature range -50 ~ 40 ºC
Sample gas pressure <1.0 MPa
Dimensions 485 mm (W) × 350 mm (H) × 600 mm (D)
Weight 40 kg
Applications
  • Petrochemical industry
  • Fluorine chemical industry
  • Metallurgical industry
  • Isotope gas analysis
Key Features

The analyzer uses quantitative models with multiple standard curves and chemometric methods to establish relationships between spectral signals and multi-component substance content. This innovative approach provides several advantages:

  • Pressure and test condition changes don't affect quantitative accuracy
  • No need for separate quantitative models per component
Highly Accurate Multi-Gas Analyzer 2s Analysis Time ≤0.2% Measurement Uncertainty for Industrial 2 Highly Accurate Multi-Gas Analyzer 2s Analysis Time ≤0.2% Measurement Uncertainty for Industrial 3
Company Achievements

JINSP Company Limited has received numerous prestigious awards and certifications including:

  • National Science and Technology Commission's Scientific and Technological Achievement Appraisal Certificate
  • China Patent Excellence Award
  • Geneva International Invention Award
  • Beijing New Technology and New Product Certificate
  • "Innovation Achievement Award" of the Zhu Liangyi Analytical Instrument Innovation Award

JINSP has participated in drafting several national and international standards, including:

  • IEC 63085 International Standard (as the only Chinese participant)
  • GB/T 41086-2021 "General Technical Requirements for Safety Inspection Equipment for Hazardous Chemicals Based on Raman Spectroscopy"
  • GB/T 40219-2021 "General Specification for Raman Spectrometer"
Highly Accurate Multi-Gas Analyzer 2s Analysis Time ≤0.2% Measurement Uncertainty for Industrial 4 Highly Accurate Multi-Gas Analyzer 2s Analysis Time ≤0.2% Measurement Uncertainty for Industrial 5 Highly Accurate Multi-Gas Analyzer 2s Analysis Time ≤0.2% Measurement Uncertainty for Industrial 6
Frequently Asked Questions
Q: This is my first time using the analyzer. Is it easy to operate?
A: We provide an English manual and instructional video to guide you through spectrometer operation. Our technicians also offer professional technical support meetings.
Q: Do you offer operation training?
A: Your technicians can receive training at our factory. JINSP engineers also provide on-site support including installation, training, debugging, and maintenance.
Q: How can I receive the best price quickly?
A: Please include detailed requirements (wavelength, detector, effective pixels, focal length, etc.) in your inquiry. We will promptly email a detailed quotation.
Q: What quality assurance measures do you have?
A: Our quality inspection team thoroughly checks all goods before shipment. We can provide inspection photos upon request.

You Might Be Into These
Get in touch with us

Enter Your Message

phoebeyu@jinsptech.com
+8618620854039
8618620854039
live:phoebe0040
8618620854039