Detail Information

Spectrual Range: 200nm - 1100nm Effective Pixels: 2048*64
Pixel Size: 28.672*0.896mm Integration Time: 4ms~900s
Dimensions: 180mm*120mm*50mm Weight: 1.2kg
Highlight:

Back-illuminated Fiber Spectrometer

,

4ms-900s Fiber Spectrometer

,

900s Fiber Spectrometer

Product Description

180mm×120mm×50mm Size Back-illuminated Fiber Spectrometer with Integration Time 4ms-900s
Product Specifications
Attribute Value
Spectral Range 200nm - 1100nm
Effective pixels 2048×64
Pixel Size 28.672×0.896mm
Integration Time 4ms~900s
Dimensions 180mm×120mm×50mm
Weight 1.2kg
Product Description
Backlit Array CCD UV Enhanced High Sensitivity Modular Spectrometer

Introducing the SR100B, a cutting-edge spectrometer designed for industrial, laboratory, and scientific research needs. With its high-performance back-illuminated CCD sensor and rapid USB connectivity, this device ensures precise spectral analysis across a broad range.

The SR100B features a Hamamatsu S10420 CCD chip, offering an expansive sensing area and exceptional spectral stability. Its 2048×64 pixel array and 14×14μm pixel size deliver superior quantum efficiency and sensitivity, making it ideal for applications spanning 200nm to 1100nm. Customizable gratings and slit widths allow for tailored spectral resolution and sensitivity, while the high-resolution light path and advanced FPGA signal processing ensure impeccable spectrum signals and dependable performance.

Detailed Technical Parameters
Detector
Chip Type Back-illuminated cooling Hamamatsu S10420
Effective Pixel 2048×64
Pixel Size 14×14μm
Sensing Area 28.672×0.896mm
Optical Parameters
Optical Design F/4 cross type
Numerical Aperture 0.13
Focal Length 100mm
Entrance Slit Width 10μm, 25μm, 50μm, 100μm, 200μm (customizable)
Fiber Interface SMA905, free space
Electrical Parameters
Integration Time 4ms~900s
Data Output Interface USB3.0, RS232, RS485, 20pin connector
ADC Bit Depth 16-bit
Power Supply 5V
Operating Current <3.5A
Physical Parameters
Operating Temperature 10℃~40℃
Storage Temperature -20℃~60℃
Operating Humidity <90%RH (no condensation)
Dimensions 180mm×120mm×50mm
Weight 1.2kg
Available Models
Model Spectral Range(nm) Resolution(nm) Slit(μm)
SR100B-G21 200~1100 2.2 (50μm)
1.5 (25μm)
1.0 (10μm)
50
25
10
SR100B-G23
SR100B-G24 200~875
350~1025
1.6 (50μm)
1.0 (25μm)
0.7 (10μm)
50
25
10
SR100B-G28 200~345 0.35 (50μm)
0.2 (25μm)
0.14 (10μm)
50
25
10
SR100B-G25 532~720(4900cm⁻¹)* 13cm⁻¹ 50
SR100B-G26 638~830(3200cm⁻¹)* 10cm⁻¹ 25
SR100B-G27 785~1080(3200cm⁻¹)* 11cm⁻¹ 50
* Primarily designed for Raman applications, with the corresponding Raman.
Key Features
  • High sensitivity - Fitted with area array back-illuminated detector with high quantum efficiency, optimizable ultraviolet band
  • High resolution - Resolution <1.0nm@10μm (200~1100nm)
  • High flexibility - 180~1100nm, compatible with multiple interfaces including USB3.0, RS232 and RS485
  • High reliability - Ultra-high SNR and excellent thermal stability
Typical Applications
  • Detect absorption, transmittance and reflection spectrum
  • Light source and laser wavelength characterization
  • OEM product module: Fluorescence spectrum, Raman spectrum, etc.
180mm*120mm*50mm Size Back-illuminated Fiber Spectrometer with Integration Time 4ms-900s 0
About JINSP Company

JINSP Company Limited, abbreviated as "JINSP", is a professional supplier with over 17 years of experience in spectral detection technology products, including Raman, FT-IR, LIBS technologies, etc. After 17 years of technology accumulation, the company's core key technologies have reached the international leading position at the level, and the cumulative number of patent applications exceeded 200.

In addition to its main headquarters located in the bustling city of Beijing, JINSP has established a fully owned subsidiary manufacturing facility situated in the province of Jiangsu, China.

JINSP Company received ISO9001:2015, ISO14001:2015, and ISO45001:2018 certifications. JINSP can provide required certifications, such as certification by the Ministry of Public Security or National Institute of Metrology, Environmental Level Certification, IP Level Certification, CE Certification, Transport Identification Report, EU ECAC certification, German ICT Security Testing, etc.

180mm*120mm*50mm Size Back-illuminated Fiber Spectrometer with Integration Time 4ms-900s 1 180mm*120mm*50mm Size Back-illuminated Fiber Spectrometer with Integration Time 4ms-900s 2 180mm*120mm*50mm Size Back-illuminated Fiber Spectrometer with Integration Time 4ms-900s 3
Frequently Asked Questions
Q1: This is the first time I use, is it easy to operate?

A1: We will send you manual and guide video in English, it can teach you how to operate the spectrometer. Also our technicians will offer professional technical operation meetings.

Q2: Can you offer an operation training?

A2: Your technicians can come to our factory for a training. JINSP engineers can go to your place for local support (installation, training, debugging, maintenance).

Q3: What's your website?

A3: You can visit: www.jinsptech.com

Q4: What about your quality assurance?

A4: We have a quality inspection team. All goods will go through quality inspection before shipment. We can send you pictures for inspection.

You Might Be Into These
Get in touch with us

Enter Your Message

phoebeyu@jinsptech.com
+8618620854039
8618620854039
live:phoebe0040
8618620854039